Elliptical diesel turbine flowmeter2022-06-29 17:28:00
Elliptical diesel turbine flowmeter

Elliptic gear flowmeter has high accuracy and is suitable for measuring the flow rate of high viscosity medium, but it is not suitable for the fluid containing solid particles. If the liquid medium is measured with gas, it will also cause measurement error.  Usually measuring resin flow meter accuracy up to 0.5 level, is a more accurate flow meter, with high measurement accuracy, small impact of liquid viscosity, no need to install straight pipe section before the table, widely used in petroleum, chemical, pharmaceutical and other oil and high viscosity media cumulative flow measurement.

Installation instructions for diesel flow Meter:

Elliptical gear flowmeter should be cleaned before installation. If the liquid contains solid particles, a filter must be installed in the upstream of the pipeline; Heavy oil flowmeter has no requirement for straight pipe section. It can be mounted horizontally or vertically.

1. The installation direction of the instrument should be the same as the direction of the arrow shown on the instrument shell and the direction of the liquid, and the installation position should be noted to facilitate reading.

 

2. The instrument should be installed at room temperature as far as possible. Do not install it in harmful gas and strong heat radiation, which may damage part of the instrument counter.

 

3. The elliptical gear should be installed in a horizontal position as far as possible, and the instant dial should be installed in a vertical position (the indexing "0" should be above, in order to reduce the friction between the two planes of the elliptical gear and the shell, and reduce the wear of parts.

 

4. The instrument is installed at the output end of the pump, if installed at the suction end, the pressure loss of the instrument filter increases the suction negative pressure of the pump, and the liquid outflow at the pump shaft also causes the error of the instrument to increase. The flange of the suction end of the pump should also prevent air leakage, otherwise it will also cause the error of the instrument to increase.

 

5. The filter should be installed in front of the instrument to prevent particles larger than 0.2 mm from passing through to prevent the instrument from being blocked by particles. The filter should be easy to clean.

 

6. Install the reverse valve before the instrument, so that the pipeline liquid can only flow one-way, to prevent damage to the counter.

 

7. The instrument is recommended as shown in the figure, with bypass and valve, which can be installed in horizontal and vertical or other directions, top-down, bottom-up, from left to right, from right to left.

Kaifeng PuSheng instrument co., LTD., mainly producing all kinds of rotor meter, the level of spiral meter, vertical spiral water meter, water meter, prepaid intelligent water meter, IC card intelligent water meter, bluetooth intelligent water meter, nb intelligent water meter intelligent water meter and valve control meter, such as photoelectric read-only meter, ultrasonic heat meter, ultrasonic water meter, electromagnetic flowmeter, the throttle device, the vortex street flowmeter,  Turbine flowmeter, and related software and hardware development, the company has intelligent circuit board and software research and development capabilities, through the ISO9000 certification system is a collection of research and development, production, sales, after-sales service, technical training as one of the high-tech production and development enterprises. 

With decades of experience in the production and service of water meters, electricity meters and other meters and calibration devices, we have the best quality control experts and scientific research and production team in China.  Company measurement experts get the measurers through certificate issued by the state in 1982, the quality control experts in 1968 (the original 983 factory), now known as artisans power of the luoyang bearing factory equipment factory work, presided over many products to participate in the national competition for weighing apparatus in China the national front row, computer industry core expert team with 20 years of experience, double card master,  And scientific research institutes, universities, as well as a number of master's doctor cooperation to set up a RESEARCH and development service team, with various aspects of the system of research and development and production capacity, flow meter by decades of experience in the flow meter technical experts carefully built supervision.  We service clients with unit of former five machine department, Beijing, Shanghai, ningbo and other places, shanxi, shandong, hebei, etc all kinds of users throughout the country, dozens of tap water company, we have training of luoyang, zhengzhou city tap water company check personnel, we have decades of instrument technical service and technical support capabilities.